Grease Removal Systems - page 37

37
Rectangular Passive Grease Interceptor Sizing Guide
Total
Operating
Inlet &
Volume Grease Volume
Dimensions
Outlet
Gallons Gallons/Pounds Length Width Height Diameter
*
500
182/1,388
5'-8"
4'-0"
4'-0"
4"
750
249/1,895
8'-4"
4'-0"
4'-0"
4"
1,000
329/2,500
11'-0"
4'-0"
4'-0"
4"
1,250
415/3,154
8'-6"
5'-0"
5'-0"
4"
1,500
499/3,789
10'-0"
5'-0"
5'-0"
4"
2,000
665/5,053
13'-4"
5'-0"
5'-0"
4"
2,500
835/6,348
16'-9"
5'-0"
5'-0"
4"
3,000
1,002/7,617
16'-9"
6'-0"
5'-0"
4"
4,000 1,332/10,120
22'-3"
6'-0"
5'-0"
4"
5,000 1,670/12,691
23'-6"
6'-0"
6'-0"
6"
6,000 2,003/15,226
24'-2"
7'-0"
6'-0"
6"
7,000 2,333/17,732
23'-3"
7'-0"
7'-0"
6"
8,000 2,666/20,265
23'-3"
8'-0"
7'-0"
6"
9,000 3,007/22,853
22'-4"
8'-0"
8'-0"
6"
10,000 3,332/25,325
24'-9"
8'-0"
8'-0"
6"
12,000 4,041/30,714
23'-9"
9'-0"
9'-0"
8"
15,000 5,062/38,475
29'-9"
9'-0"
9'-0"
8"
20,000 6,744/51,252
35'-8"
10'-0"
9'-0"
8"
25,000 8,417/63,973
39'-4"
10'-0"
10'-0"
8"
30,000 10,093/76,714
47'-2"
10'-0"
10'-0"
8"
Width
Length
OUTLET
INLET
Influent Flow
Diffusion Baffle
Manway
Striker Plate
Grease Dam
Vent Fitting
Level Sensor Port
Rectangular Double Basin
Indirect Effluent
Flow Transfer Baffle
Sludge Baffle
Height
Options
• Custom sizing and configurations
available per AHJ requirements
• Stainless steel construction
• Double-wall construction
• OSHA Ships Ladder or Stairs
• Manway Extensions
• Platforms
• Thermal Insulation
• Immersion Heaters
• OSHA Handrail around top of tank
• Easily accessible Sampling Ports
for grease interceptor monitoring
• FOGSWatch Monitoring System
• Effluent Filters
• Influent or Effluent Pump Systems
*Available as double-basin ONLY.
Complies to IAPMO UPC
Gravity Grease Interceptor (GGI) sizing and construction is consistent with industry protocol for
complying with the sewer pre-treatment regulations. GGI sizing is based on 30-minute retention time.
Consult Highland Tank for alternate sizing methods. Inlet diameter/flow must not exceed that of the
outlet. Improper pumping of wastewater into the PGI can result in increased turbulence and less
efficient separation; consult Highland Tank for influent pumping system selection.
Interior Lining
Custom designs are available to
meet AHJ requirements.
1...,27,28,29,30,31,32,33,34,35,36 38,39,40,41,42,43,44,45,46,47,...58