Wastewater Treatment Systems - page 22

22 •
Diameter
Cylindrical Separator Sizing Guide
Flow
Total
Recommended
Inlet &
Model
Rate
Volume
Oil Pump-out
Outlet
HT or HTC Gal/Min
Gallons
Gallons
Diameter
Length
Diameter
350
35
350
70
3'-6"
6'-0"
4"
550
55
550
110
3'-6"
7'-9"
4"
1,000
100
1,000
200
4'-0"
10'-9"
6"
2,000
200
2,000
400
5'-4"
12'-0"
6"
3,000
300
3,000
600
5'-4"
18'-0"
8"
4,000
400
4,000
800
5'-4"
24'-0"
8"
5,000
500
5,000
1,000
6'-0"
23'-10"
8"
6,000
600
6,000
1,200
6'-0"
28'-8"
10"
7,000
700
7,000
1,400
7'-0"
24'-4"
10"
8,000
800
8,000
1,600
7'-0"
28'-0"
10"
9,000
900
9,000
1,800
8'-0"
24'-0"
12"
10,000
1,000
10,000
2,000
8'-0"
26'-8"
12"
12,000
1,200
12,000
2,400
8'-0"
32'-0"
12"
15,000
1,500
15,000
3,000
10'-0"
25'-6"
14"
20,000
2,000
20,000
4,000
10'-6"
31'-0"
16"
25,000
2,500
25,000
5,000
10'-6"
38'-9"
18"
30,000
3,000
30,000
6,000
10'-6"
46'-6"
20"
40,000
4,000
40,000
8,000
12'-0"
47'-3"
24"
50,000
5,000
50,000
10,000
12'-0"
59'-6"
24"
60,000
6,000
60,000
12,000
13'-0"
60'-6"
24"
Plate spacing and orientation may vary depending on site conditions. Custom sizing is available.
Consult Highland Tank for Series G & J sizing information.
Length
Flanged Manway & Cover with Gauge Port
2" Diameter Interface & Level Sensor Pipe
4" Diameter Oil Pump-Out Pipe
Flanged
Inlet Pipe
Lifting Lug
Gravity Discharge
Option Shown
Wear Plate
Corella
®
Parallel
Plate Coalescer
Sludge
Baffle
Petro Screen
Coalescer
Striker
Plate
OUTLET
INLET
Flanged
Outlet Pipe
Underflow
Baffle
Velocity Head
Diffusion Baffle
Vent Fitting
Dimensions
1...,12,13,14,15,16,17,18,19,20,21 23,24,25,26,27,28,29,30,31,32,...58